Architectural Preset ControlInstaller's ManualPublication 21-1049 Rev B22 Feb 2013Leprecon, LLCP.O. Box 21810087 Industrial DriveHamburg, MI 4813
106. Electrical hookupFor APC only systems (no DMX controller), CAT5 cable with Ethernet type RJ45connectors is used to interconnect panels and the d
11If the system does not include the APC Hub, DMX data connections to the panel areshown below:XLR Pin Function Color RJ45 Pin1Common white / green32D
127. ConfigurationOnce all APC panels in the system are correctly cabled, the next step is to configurethe panels for proper operation. Jumpers on th
13Notes regarding each jumper option:1 - TerminationIn a properly configured DMX system, there is a single transmitter, many receiversconnected in a d
148. Installing panels and faceplatesAPC panels consist of three parts:· Faceplate - 1/8" aluminum snap-on cover, painted and screened.· Mount
159. ProgrammingAPC panels record and play back 512 DMX channels for each preset provided.When the APC panels are wired, mounted and energized, prese
16To Record Presets:1. Make sure the face plate is removed from the Master panel.2. Turn on the DMX controller. The Record LED behind the front pane
1710. Preset PlaybackOnce presets are recorded, the APC system is ready for use.If there is no control console in the system, or if the console is tu
2Table of Contents1. Overview 32. Specifying a system 33. Using the APC Hub 54. Power Requirements 95. Mounting requirements 96. Electrical hooku
31. OverviewThe Leprecon Architectural Control Panel system (APC) is a wall-mounted DMXcontroller that can be used with any type of DMX compatible di
4· Leprecon APC panels use reserved DMX start codes to communicate with eachother inside the system. For this to work, all APC panels must be connect
53. Using the APC HubThe Leprecon APC Hub provides several important functions in an APC panelsystem.1. DC power - the Hub will power up to ten APC
6Rear panel connectionsThe rear panel of the APC Hub contains all of the connectors needed to interfaceto the lighting system.1. AC Power Input - IEC
7Front panel connectionsThe front panel of the APC Hub includes three LED indicators:1. Power - this LED is lighted if the internal power supply is w
88. Power the Hub back on, check for the Power indicator.9. Program the panels as detailed elsewhere in this manual.
94. Power RequirementsAPC panels require DC power for operation. The power is applied on the RJ45cabling that also carries DMX signal from panel to p